CategorySourcing & Buying Guides
Titanium mesh size:
look beyond the mesh count.
Connect the construction to the clear opening, wire diameter, projected open area and usable delivered shape before comparing quotations.

Quick answer
Order titanium mesh using its construction, material designation, weave, aperture, wire diameter, count convention and delivered dimensions. For ideal square woven mesh, pitch in millimeters is 25.4 divided by openings per inch, aperture is pitch minus wire diameter, and projected open area is 100 × [aperture/(aperture + wire diameter)]². These equations do not establish a filtration rating or installed flow capacity. Agree tolerances, orientation, usable area, fabrication and inspection so the quotation describes the product the task actually needs.
01 / Construction and task
Identify the mesh construction before comparing sizes.
A buyer requests 20-mesh titanium for a replacement screen and receives two different quotations. Both suppliers use the same mesh count, but one offers thinner wire and a larger opening. Another enquiry asks for titanium mesh when the drawing actually shows expanded sheet. These are not merely differences in vocabulary. The construction determines which dimensions describe the product and which calculations are valid. Begin by identifying what the existing component does and how the proposed material is made.
Woven wire cloth consists of interlaced wires. Welded wire mesh joins intersecting wires at their crossings. Expanded metal is produced from slit and stretched sheet, while perforated sheet contains openings made through a sheet. A square-woven-wire equation cannot be applied directly to the diamond openings and strands of expanded metal. Likewise, a perforated-sheet hole diameter does not define woven-wire diameter. Use the construction name on the enquiry and attach a drawing or clear reference image where the terminology is uncertain.
Within woven products, preserve the weave and opening form. A square-aperture cloth, a rectangular-aperture cloth and a dense filter weave are different structures. The simple examples in this guide use ideal square openings with equal wire diameter and pitch in both directions. They are useful for checking a quotation, but they do not describe every weave. GKD’s plain Dutch weave information illustrates a dense structure with a filtration path different from a visibly open square grid; its stainless-steel product data should not be treated as titanium availability. [1]
Define the task next. A screen used to separate particles needs a different acceptance discussion from mesh used as a support, protective panel or electrode substrate. For screening, ask which opening and distribution matter. For a fabricated support, include shape, stiffness-related design requirements and attachment. For an electrode application, distinguish an uncoated titanium substrate from any specified active coating and electrical arrangement. A generic mesh designation does not authorize a substitution between those functions or establish process performance.
| Construction | Useful starting dimensions | Do not substitute |
|---|---|---|
| Square woven wire cloth | Opening, wire diameter, count and weave | Count alone for the complete geometry |
| Expanded titanium sheet | Long/short opening dimensions, strand and thickness | A square-wire formula |
| Perforated titanium sheet | Hole geometry, pitch, pattern and sheet thickness | Woven-wire diameter |
| Dense filter weave | Defined construction and tested filtration requirement | A visible square-aperture assumption |
Record the titanium material designation separately from the mesh geometry. Include the required condition, surface preparation and material documentation where specified. “Titanium mesh” by itself does not identify every alloy, temper or finished treatment. If the application owner has not selected a material, request a clearly labeled candidate for review. The result should be an enquiry that connects one defined construction to one intended task, so suppliers can explain a real deviation rather than answering different interpretations of the same short phrase.
02 / Count, aperture and units
A mesh count needs a wire diameter.
For the convention used here, mesh count n is the number of openings per linear inch in each direction. It is not a number of holes per square inch, and it is not an opening measured in micrometers. Confirm the supplier’s convention rather than assuming that an unexplained number uses the same basis. For ideal regular square mesh, pitch p is 25.4/n millimeters, and clear aperture w is p minus wire diameter d. Universal Wire Cloth documents the corresponding relationships between centers, opening, diameter and count. [2]
Consider two hypothetical 20-mesh offers. Their nominal pitch is 25.4/20 = 1.27 mm. With 0.40 mm wire, the calculated clear opening is 0.87 mm, or 870 µm. With 0.50 mm wire, it is 0.77 mm, or 770 µm. Both have the same nominal mesh count, yet their calculated apertures differ by 0.10 mm. This example does not establish an available titanium specification or a tolerance; it shows why the wire diameter must appear beside the count in a comparable quotation.
Use consistent units throughout the calculation. One millimeter equals 1,000 micrometers. Converting 0.87 mm to 870 µm changes the unit, not the mesh count. A lookup table that assigns one micron value to “20 mesh” is using an assumed wire specification or a named sieve convention. Identify that assumption before using the table for industrial cloth. A standard test-sieve designation and a commercial mesh-count description should not be treated as interchangeable order information without checking their definitions.
For a rectangular pattern, record both directions. The warp and weft may have different counts, wire diameters or openings. State the supplier’s order of notation and identify the orientation on a cut-part drawing. A description such as 20 × 30 cannot safely be simplified to 20 mesh. It also cannot be rotated in a fabricated part without considering the intended direction. Where the product is dense or calendered, use its defined construction and acceptance method instead of forcing the square-grid equation onto it.
| Hypothetical square mesh | Pitch | Wire diameter | Calculated aperture |
|---|---|---|---|
| 20 openings/inch | 1.27 mm | 0.40 mm | 0.87 mm / 870 µm |
| 20 openings/inch | 1.27 mm | 0.50 mm | 0.77 mm / 770 µm |
When an enquiry contains count, diameter and aperture, check that the nominal numbers are mutually consistent within the stated rounding. If they are not, ask which dimension controls and request a corrected description. Do not silently change one value to make the arithmetic work. A copied catalogue line may combine two neighboring specifications, or a conversion may have been rounded too aggressively. Resolving that discrepancy before ordering is easier than deciding which of three conflicting numbers governs a delivered roll.
For a replacement identified from a sample, distinguish measured observations from the proposed specification. Record the measuring direction and condition, and avoid using a damaged edge as the only reference. The original drawing or accepted specification should govern whenever available. If reverse identification is necessary, have the responsible technical reviewer approve the resulting nominal geometry and limits before it becomes the repeat-order description.

Hypothetical 20-mesh square geometry: 1.27 mm pitch minus 0.40 or 0.50 mm wire gives 0.87 or 0.77 mm aperture.
03 / Open area and usable flow face
Calculate open area without turning it into a flow guarantee.
For ideal square mesh, the projected open-area percentage is 100 × [w/(w + d)]². It compares the clear opening area with the repeating cell area in a flat projection. The square is necessary because the opening occupies two directions. This is a geometric measure; it is different from the three-dimensional void fraction of a filter medium, its tested particle retention and the flow capacity of a complete installed element. Keep those terms separate in the purchase specification.
The two illustrative 20-mesh examples produce different projected open areas. At w = 0.87 mm and d = 0.40 mm, the result is approximately 46.93%. At w = 0.77 mm and d = 0.50 mm, it is approximately 36.76%. Those values explain why equal count does not mean equal open surface. They do not justify claiming a proportional change in actual flow, pressure loss or production output. Such performance depends on the medium, fluid, support and operating conditions.
Another comparison holds the aperture constant. With w = 0.50 mm and d = 0.25 mm, ideal open area is 44.44%. With the same opening and d = 0.125 mm, it becomes 64.00%. The second geometry has more open projected area, but changing wire diameter also changes the structure that must be reviewed for the intended support and fabrication. Purchasing should not choose the larger percentage automatically. Ask the application owner which opening, mechanical and installation requirements must all be retained.
Installed area can be smaller than the purchased panel. Suppose a hypothetical 200 × 300 mm panel has only a 160 × 260 mm clear window after its frame covers the edges. The exposed face is 41,600 mm². At an unrounded open fraction of 4/9 (approximately 44.44%), the ideal projected openings within that window total about 18,489 mm², or 30.8% of the gross panel area. This simple estimate excludes support bars, seals, overlap and fouling. It is an area-accounting illustration, not a filter-sizing calculation.
| Quantity | What it describes | What it does not prove |
|---|---|---|
| Mesh open-area percentage | Ideal projected geometry | Installed flow capacity |
| Exposed window area | Face not covered by the frame | Absence of support blockage |
| Tested retention | Performance under a defined method | Every operating condition |
| Pressure-drop data | Specified fluid, flow and element condition | Unchanged behavior after loading |
For a rectangular ideal grid, the open fraction is the product of the clear-opening fraction in each direction: [wx/(wx + dx)] × [wy/(wy + dy)]. Define which wire dimension blocks each direction before calculating. Do not reuse the square expression when the two directions differ. Where the structure has overlapping layers or a tortuous pore path, obtain the appropriate supplier characterization and project acceptance requirement instead of presenting this projection as a pore model.
If a supplier offers filtration or permeability data, ask for the test conditions and the exact construction represented. GKD’s technical literature distinguishes retention, permeability, porosity and bubble-point measurements. That distinction is useful when writing an enquiry: request the property needed by the application, with its method, rather than expecting one open-area number to answer all performance questions. Reference data for another metal or construction is background information until the actual titanium product has an agreed basis. [3]

Illustrative panel: 200 × 300 mm gross, 160 × 260 mm exposed, ideal open fraction 4/9. About 18,489 mm² projected opening before other blockage.
04 / Tolerance and inspection
Specify how the opening will be assessed.
A nominal aperture is a target description, not a statement that every opening is exactly identical. Woven material has dimensional variation, and the acceptance rule must identify which characteristics are controlled. Ask for the applicable standard or agreed specification, its edition, the nominal aperture and wire diameter, and the relevant permissible variation. Avoid inventing a universal percentage tolerance for every titanium mesh. The correct requirement depends on the construction, size and intended function.
ISO 9044:2016 addresses industrial square-aperture woven wire cloth for screening, including nonferrous materials within its scope. Its public description excludes certain constructions, including cloth coated after weaving and pre-crimped or welded screens. It also notes limited application outside screening, where other requirements may need agreement. Cite it only when it applies to the product and task, and use the controlled standard for actual acceptance limits. A broad statement of ISO compliance is not a substitute for identifying the ordered construction. [4]
Average spacing and individual opening limits answer different questions. Measuring a row of pitches can improve the estimate of average geometry, but an acceptable mean does not demonstrate that no isolated opening is oversized. A hypothetical row with ten intervals spanning 12.70 mm has a mean pitch of 1.27 mm. Subtracting a representative 0.40 mm wire diameter gives a nominal-style average opening estimate of 0.87 mm. The calculation alone does not establish the maximum individual opening or the whole roll’s conformity.
Haver & Boecker describes row measurement and wire-diameter assessment methods for woven cloth. For purchasing, specify which method and sampling arrangement the quality team will use and how the results are reported. The appropriate tool depends on the opening and wire size; very fine features may require optical measurement. Do not specify an arbitrary instrument resolution without considering measurement capability and the agreed tolerance. The supplier and receiving inspector should be able to evaluate the same requirement. [5]
| Inspection item | Question to resolve |
|---|---|
| Opening geometry | Mean, individual limits and both directions? |
| Wire diameter | Nominal input or finished woven condition? |
| Roll or panel condition | Permitted distortion, damage and edge condition? |
| Sampling | Which positions, quantity and record format? |
| Functional rating | Which test method and acceptance condition? |
Specify the condition of measurement. A mesh panel held under tension may not present exactly the same geometry as a loose sample. Cutting, forming and handling can also alter local shape. If the finished assembly is the acceptance item, identify whether inspection occurs before or after those operations and which condition governs. Preserve orientation marks when samples are taken so a result can be related to the original roll direction.
Receiving inspection should preserve evidence when a discrepancy appears. Photograph the package and affected area, record the lot and location, and retain a representative sample under the agreed procedure. Do not stretch or rework the material to make it appear compliant before the supplier reviews it. A clear record of the measured condition allows both parties to distinguish an original dimensional issue from damage introduced during cutting, mounting or transport.
05 / Rolls, cut pieces and fabrication
Buy usable geometry, not only nominal square meters.
The supply format determines how much of a delivery can become the required part. Specify roll width and length, minimum usable dimensions, permitted joins or separate lengths, and whether edges are included in the stated width. For cut pieces, provide the finished outline, dimensional tolerance, corner details, orientation and edge condition. A quotation for ten square meters of roll cloth is not equivalent to a quotation for a defined number of accepted, ready-to-fit panels.
Separate woven selvage from a cut edge and state which condition the fabrication process needs. Loose wire ends, fraying and distortion near an edge can affect handling or attachment. A nominal roll width does not automatically establish a clean usable width for every cut part. Ask whether trimming is included and how edge regions are treated in the agreed acceptance basis. If the supplier provides an oversize blank for later trimming, identify the machining or fabrication allowance explicitly.
An original layout example shows why area alone can mislead. Assume a 1,000 × 2,000 mm usable sheet, rectangular blanks of 300 × 400 mm, 10 mm margins on all outer edges and 5 mm gaps between blanks. With the 300 mm side across the sheet, three columns need 930 mm including margins and two gaps. Four rows need 1,635 mm including margins and three gaps. Five rows would need 2,040 mm, so that particular orientation yields twelve blanks. This is a simple layout example, not a claim that it is the optimal nesting solution.
The example assumes the entire stated sheet is usable and that the chosen spacing suits the approved cutting process. Real orders must also account for dimensional tolerances, permitted defects, sample coupons and fabrication losses. Rotation might improve yield in some cases, but it may be prohibited by a directional weave or the drawing. Preserve the orientation requirement before optimizing a cutting plan. An apparently economical area price can become expensive if the supplied width cannot produce the intended panels.
| Supply format | Details to quote |
|---|---|
| Roll | Usable width, lengths, edges, joins and winding protection |
| Flat cut piece | Outline, tolerance, orientation and edge condition |
| Formed component | Drawing, forming direction, seams and attachment |
| Framed or multilayer assembly | Layer order, support, frame, sealing and acceptance stage |
For formed cylinders, baskets or framed screens, include the fabrication drawing and the required state after joining. A correct flat cloth can still produce an unacceptable assembly if its seam, support or attachment blocks the intended active area or changes the outline. Do not infer welding or forming capability from the raw-mesh description. Ask the supplier to identify which fabrication steps are included, which are outsourced if disclosure is required, and what finished inspection accompanies the component.
Packaging should preserve the purchased geometry. Rolled material needs protection against crushing and handling damage; flat panels need an agreed support and separation arrangement. Keep each piece or bundle connected to its lot when it is divided. If a roll contains multiple lengths, list them rather than quoting one uninterrupted total. The receiving team can then compare usable pieces with the order instead of discovering a short segment only when the cutting plan begins.

Hypothetical orientation: twelve 300 × 400 mm blanks on 1,000 × 2,000 mm usable material, with 10 mm outer margins and 5 mm gaps. Not an optimized nesting plan.
06 / Quotation and trial
Turn the specification into a repeatable purchase.
A complete titanium-mesh enquiry starts with the task and construction, then states material, weave, opening, wire diameter, count convention, dimensions and quantity. Add surface condition, inspection, documentation and any fabrication drawing. Mark provisional values clearly. If the supplier proposes a different wire diameter to improve availability, request the resulting aperture and open area as a separate alternative. Do not let a change in one field disappear behind an unchanged mesh-count label.
Use a comparison sheet with one line per requirement. Record the requested value, offered value, supporting document and acceptance status. If both suppliers meet the same geometry but one excludes cutting or inspection, keep that difference visible in the commercial comparison. Ask whether quantity means gross area, net usable area or accepted finished pieces. Clarify minimum order, split-roll lengths and packaging, because these can change the practical value of a quotation without changing its unit price.
| RFQ group | Information that closes the gap |
|---|---|
| Identity | Titanium designation, construction and weave |
| Geometry | Aperture, wire diameter, count convention and orientation |
| Delivered form | Usable roll dimensions or finished-part drawing |
| Acceptance | Limits, method, sampling and records |
| Trial | Purpose, sample configuration and approval responsibility |
Define the trial question before requesting a sample. A small coupon can help assess appearance, geometry and handling, but it may not represent a full framed element or an operating filter. If the task is filtration, the process owner should establish the appropriate test conditions and performance requirement. If the task is fabrication, use the intended forming and attachment route. Label a preliminary sample as preliminary so that its acceptance does not automatically approve an altered production construction.
Keep retention claims tied to a stated test. The word micron can describe an opening dimension or a filtration rating, and those are not automatically equivalent. Ask what is measured, under which method, with which medium and acceptance criterion. Do not promise complete capture of every irregular particle based only on ideal aperture geometry. A sample that performs well in one clean laboratory condition may need further review for the actual operating load, cleaning cycle and support arrangement.
Document requirements should follow the project rather than a generic list of impressive certificates. Specify the material evidence, dimensional results and functional records actually required, with a link to the delivered lot. A certificate for input wire does not automatically describe a finished framed screen. If the mesh is cut into several components, preserve the traceability needed by the buyer’s procedure. Identify which party accepts the records and when unresolved deviations must be closed.
After a successful trial, freeze the approved construction and supply condition in a repeat-order description. Include drawing revision, orientation, finish, usable dimensions, inspection and any controlled process requirement. Changes in wire diameter, weave, coating or fabrication should trigger the agreed review. For a defined supply enquiry, see TiHubs titanium mesh and perforated-sheet products. State which construction is required so the proposed offer can be evaluated against the actual task.
07 / Build your RFQ
Prepare a titanium mesh enquiry.
Send the intended task and construction together with aperture, wire diameter, count convention and required roll or cut-part dimensions. Include titanium designation, surface condition, quantity, inspection and destination. TiHubs can review the requested supply scope; alternatives should show which geometry or fabrication requirement changes so the application owner can assess them.
Information to include
- Construction, weave and intended task
- Titanium designation and surface condition
- Aperture, wire diameter and count convention in both directions
- Usable roll dimensions or finished-part drawing
- Orientation, edges, fabrication and packaging
- Acceptance limits, records, quantity and destination
Build your RFQ checklist
Choose the product and add the information you have. Copy the resulting brief or send your requirements to TiHubs. Submitting an enquiry does not place an order.
08 / FAQs
Questions buyers ask
Does 20 mesh have one fixed aperture in microns?
No. Under an openings-per-inch convention, 20 mesh sets a nominal pitch of 1.27 mm, while the wire diameter determines the remaining clear opening. A conversion chart uses a particular wire or sieve specification. Request that basis before treating its micron value as the purchase requirement.
Are mesh count and holes per square inch the same?
No. The convention used here counts openings along a linear inch in each direction. A two-dimensional hole count is a different quantity. State the counting convention and both directions, particularly when the weave or opening is rectangular.
Does more open area guarantee proportionally more flow?
No. Open area is a projected geometric ratio. Actual flow and pressure loss depend on fluid properties, support, construction, loading and the installed element. Request performance data under defined conditions if flow capacity is part of the acceptance requirement.
Can I apply these equations to expanded titanium mesh?
No. The square-woven-wire formulas assume interlaced wires with regular clear openings. Expanded metal requires its own opening, strand and thickness description. Perforated sheet and dense filter weaves also need construction-specific dimensions and acceptance methods.
Is a mean opening measurement enough for acceptance?
Only if the agreed requirement says so. A mean does not automatically establish maximum individual openings, defect limits or the complete roll condition. Define the applicable standard, characteristics, sample locations and measurement method before delivery.
Should I order by square meters or finished pieces?
Use the basis that matches the supply scope. Roll area may require trimming, cutting and fabrication, while finished pieces can include those operations. Compare usable dimensions, orientation, edges, permitted separate lengths and inspection rather than assuming equal gross area gives equal accepted output.
09 / Key takeaways
Keep the purchase requirements connected.
- Identify construction before using a mesh-size formula.
- Pair mesh count with wire diameter and aperture.
- Keep geometric open area separate from tested performance.
- Specify usable dimensions, orientation and edge condition.
- Agree inspection and freeze the approved repeat-order description.
Technical references
Sources and data scope
References reviewed November 13, 2026. Public source summaries support the discussion; the controlled specification, agreed edition and approved project requirements govern acceptance.
- GKD — Plain Dutch weave construction — Illustrates a dense filter-weave structure; listed stainless-steel availability is not titanium availability.
- Universal Wire Cloth — Mesh dimensions and formulas — Definitions of count, wire diameter, centers and clear opening; article calculations use explicit units and ideal geometry.
- GKD — Woven expertise: industry and filtration — Distinguishes geometric and tested performance characteristics and their measurement conditions.
- ISO 9044:2016 — Industrial woven wire cloth — Public scope and exclusions; consult the controlled edition for acceptance limits.
- Haver & Boecker — Wire mesh measurement methods — Primary guidance on wire diameter, pitch and aperture measurement.