Titanium condenser tube bundle and U-bent heat exchanger tube on a dark surface

Titanium
condenser tube

Titanium tubing for condensers, evaporators and heat exchangers. Match tube dimensions, manufacturing route and inspection to the equipment design, tubesheet connection and service environment.

View specifications
20 years in titanium100+ Baoji factory connections
Tube integrity. Tubesheet fit. Equipment context.

Specify the heat-transfer tube set

Straight tubing, U-bent lengths and replacement sets need different geometry and release information. Tubing supply does not include thermal design unless separately agreed.

Straight condenser tubes

Straight condenser tubes

Provide OD, wall, cut length and the required standard. State whether wall is ordered on a nominal or minimum basis and identify the tubesheet connection method.

  • OD, wall basis and length
  • Seamless or welded route
  • Tubesheet connection context

Define your condenser & heat exchanger tubes

Send the operating conditions and drawing requirements. Materials, feasibility, quantity, lead time and acceptance are confirmed through project review.

Order itemInclude in your enquiryWhy it matters
Equipment contextCondenser / evaporator / exchanger and dutySets the intended tube application
Product standardASTM B338 or specified route and editionDefines tube acceptance scope
Material and routeGrade, seamless or welded construction and conditionControls material and manufacturing basis
Tube dimensionsOD, wall basis, tolerances and cut lengthMatches the equipment drawing
Connection detailsTubesheet fit, end finish and joining methodCoordinates assembly interfaces
Bend geometryU-bend drawing, radii, legs and bend acceptanceDefines formed-tube requirements
Integrity testingRequired NDT, leak / pressure tests and criteriaSets tube-level verification
Delivery packageQuantity, spares, traceability and protected packingSupports assembly and receiving inspection

Your starting specification.

Customer Feedback & RFQ Form (#6)

Include equipment duty, tube standard and grade, seamless or welded route, OD, wall basis, length, bend drawing, quantity and test requirements.

Dimensions, availability and acceptance criteria are confirmed in the quotation and order documents. Product photographs illustrate the supply format.

Start with the grade

Explore a material guide, then tell us the exact designation required by your drawing or purchase specification.

Chinese designations and international names are reference routes, not automatic substitutes. Grade, product specification, condition and acceptance requirements must be agreed together.

Open grade cross reference ↗

Applications, with conditions

The process, operating environment and required outcome help define the structure, materials and acceptance scope.

Surface condensers

Condenser tube procurement must align with the equipment design and cooling-water conditions. Specify the chosen grade and joining requirements; the tube supplier should not infer a universal corrosion or thermal rating.

What to sendCooling medium, equipment drawing, tube dimensions and required acceptance.

Evaporators and process exchangers

Process-side chemistry and cleaning conditions influence material selection. Give the fabricator the required tube route, condition and testing so the material package matches the equipment specification.

What to sendProcess and cleaning conditions, selected grade and fabricator requirements.

Maintenance and retubing

Replacement programmes need verified dimensions and a count linked to the equipment. Include removal or installation constraints and any planned change from the original material or wall.

What to sendAs-built records, verified measurements, quantity and planned service changes.

Connect tube supply to the tubesheet

The tube specification, connection detail and equipment acceptance plan should be reviewed together before manufacturing the complete set.

Heat exchanger tube end-preparation illustration / assembly interface control

OD and wall basis · straight length · U-bend radius · leg spacing · tube-end finish

Order geometry schematic; not a dimensional product drawing.

Confirm the ordered tube route

State the standard, edition, alloy and seamless or welded construction. Check required tests against that precise route and any project supplements.

Freeze dimensions and connection details

Agree OD and wall tolerances, nominal or minimum wall basis, length and end preparation. Confirm the tubesheet fit with the equipment designer.

Define forming and supplementary checks

For U-bends or other formed tubing, specify the drawing and bend acceptance. Identify treatment and inspection after forming where required.

Release a traceable tube set

Connect heat identity, dimensions and test records to the delivered bundles. Protect tube bores and ends for transport and storage before assembly.

Inspection, agreed upfront

Specify the tests and documents that your receiving inspection needs. Scope, sampling and acceptance levels belong in the order.

Dimensional inspection illustration / agreed scope and acceptance
Order documentationTiHubs

Traceable from heat to shipment.

Material identificationGrade + specification
Batch identificationHeat / lot reference
Inspection scopeAgreed tests & results
Shipment identificationMarks + packing list
Illustrative document checklist. Not a certificate or test report.
01Material and route

Verify grade, condition and construction route.

Ordered specification
02Wall basis

Check nominal or minimum wall requirements.

Defined thickness acceptance
03Tube geometry

Inspect OD, length and straightness.

Assembly dimensions
04Formed regions

Check bends against the agreed drawing and limits.

Post-forming acceptance
05Integrity evidence

Review specified NDT and leak / pressure tests.

Tube-level test records
06Tube-set identity

Keep heat, bundle and quantity records connected.

Traceable assembly input

Titanium Condenser & Heat Exchanger Tubes references

Reference documents for condenser & heat exchanger tubes procurement. Confirm product scope, grade, delivery condition and the edition required by your order.

Library PDFs may be earlier editions. Check the document cover and your contractual revision. A reference file does not certify a supplied product.

Explore all downloads ↗

Baoji.
One contact.

TiHubs coordinates titanium sourcing through a local manufacturer network. Your specification guides the supplier review, technical discussion and delivery requirements.

20 yearsTitanium industry experience
100+Baoji factory connections
  1. Clarify the requirement

    Confirm grade, dimensions, state, quantity and the purpose of the stock.

  2. Review the supply route

    Discuss manufacturing, finishing, inspection and documentation with the relevant supplier.

  3. Agree the commercial scope

    Confirm the quotation, lead time, acceptance requirements and delivery terms.

  4. Coordinate inspection & delivery

    Follow the agreed checks, marking, packing and shipment documentation.

Before you order

Answers to the details that make your titanium condenser & heat exchanger tubes enquiry easier to review.

TITANIUM CONDENSER & HEAT EXCHANGER TUBES · BAOJI SOURCING

Send your specification.

Titanium tubing for condensers, evaporators and heat exchangers. Match tube dimensions, manufacturing route and inspection to the equipment design, tubesheet connection and service environment.

You do not need to finalize every detail before contacting us.

Start your RFQ

Required fields *

Customer Feedback & RFQ Form