Titanium vacuum flanges.
Send the mating port or component drawing as well as the nominal size. Identify the knife edge and gasket, flange orientation, tube or chamber interface and the boundary that must be leak tested.
Select the supply configuration
Use the drawing and the assembly configuration to identify the item to quote.
Flush-mount flange
For the quotation, identify wall section, sealing plane, access for attachment.
- Wall section
- sealing plane
- access for attachment
Dimensions and acceptance
Specify a titanium CF vacuum flange by mating interface, outside diameter, gasket, mounting and bolt pattern. Compare published DN40 and DN200 examples, cleaning and leak-test evidence.
| Order item | Include in your enquiry | Why it matters |
|---|---|---|
| Atlas TICF-0275-04 | Flush mount, listed 2.75 in / 70 mm, DN40 | Manufacturer’s nominal flange size pairing, distinct from measured clear bore |
| Atlas TICF-1000-04 | Flush mount, listed 10.00 in / 254 mm, DN200 | Same mounting family, different nominal interface |
| Exact unit conversion | 2.75 in × 25.4 = 69.85 mm | The published 70 mm is a catalogue label. Use the part drawing for acceptance. |
| Atlas series material example | Grade 2 flange and knife-edge face, Grade 5 by enquiry | Catalogue also describes an aluminium 6061-T6 rotatable collar option for clearance holes |
| ISO 3669:2026 | Dimensional scope for fixed and rotatable bolted knife-edge vacuum flanges | A dimensional reference and a measured assembly leak rate are separate evidence |
Your starting specification.
Send the mating port or component drawing as well as the nominal size. Identify the knife edge and gasket, flange orientation, tube or chamber interface and the boundary that must be leak tested.
The table identifies the basis for the quotation. Confirm material, dimensions, inspection and delivery for the selected part before ordering.
Material and delivery condition
Identify the material on the approved drawing and confirm its product form and condition with the quotation.
Chinese designations and international names are reference routes, not automatic substitutes. Grade, product specification, condition and acceptance requirements must be agreed together.
Open grade cross reference ↗Purchasing situations
A first assembly, a replacement and a repeat order need different evidence.
Flush-mount flange
For the quotation, identify wall section, sealing plane, access for attachment. For related supply options, see the parent product guide.
Tube-mount flange
For the quotation, identify tube OD and wall, bore transition, alignment.
Blank or modified port
For the quotation, identify blind or bored, clocking, leak-test boundary.
Engineering and purchasing guide
Send the mating port or component drawing as well as the nominal size. Identify the knife edge and gasket, flange orientation, tube or chamber interface and the boundary that must be leak tested.

Nominal interface and outside diameter. DN label, Flange OD.
Order geometry schematic; not a dimensional drawing.Identify the vacuum interface before the metal
Start a titanium vacuum flange enquiry at the mating port. Identify the flange family, the existing part or chamber drawing, the sealing mechanism and the nominal designation. A circular titanium flange with evenly spaced holes could be intended for several incompatible systems. A CF interface uses opposed knife edges and a deformable metal gasket. A KF connection uses a different centring and sealing arrangement with a clamp and an elastomer O-ring in common instrument designs. A process-piping flange has its own standards, facings and duties. A similar outside diameter or the common word vacuum does not make these assemblies interchangeable.
Sketch a section through the port that shows what remains on the chamber and what the customer wants supplied. The quotation might cover a loose flange, a blank to close a port, a flange attached to a tube stub or a finished port welded into a chamber wall. Show the side exposed to vacuum and the side accessible for fasteners. Mark the surface where the joint seals. If the buyer needs an adapter between different interface families, name both ends individually. Selecting a gasket for one end will not resolve an incompatible bolt or clamp arrangement on the other. Identify who owns the connection between those ends and what acceptance will cover it.
A vacuum chamber can contain components from several suppliers and standards generations. A nameplate or procurement record can help identify a port, but the mating drawing is more reliable for establishing the actual geometry. Record the manufacturer’s part number, revision, nominal size and any modification made after purchase. A custom chamber may have had a flange modified for a sensor, a rotated pattern or a different tube size. Where an existing part is only identified by a photograph, ask for front and side views with a scale, and mark which face is shown. Treat measured details and assumed designations as separate entries until the controlling drawing is confirmed.
Use a flange family’s material description carefully. A titanium sealing face can be supplied with a collar or hardware made of another metal. In the Atlas family linked below, the manufacturer identifies Grade 2 titanium for the standard flange and knife-edge face, Grade 5 by enquiry, and a 6061-T6 aluminium collar option for a rotatable clearance-hole construction. Which parts are present depends on the selected configuration. Identify all materials that matter to the owner, including the gasket and fasteners. If magnetic response, cleanliness or material compatibility matters to a laboratory process, define the requirement for the installed arrangement rather than assuming that identifying titanium on the flange resolves the entire assembly.
Read nominal size, flange OD and clear bore separately
A catalogue may describe a flange with an inch-based outside size, a rounded metric size and a DN designation on the same line. These labels describe different conventions. They are not three independent dimensions that every surface must match. Atlas lists TICF-0275-04 as a flush-mount titanium flange with the designation 2.75 inches, 70 millimetres and DN40. Its TICF-1000-04 is listed as a 10.00 inch, 254 millimetre, DN200 flush-mount flange. DN40 and DN200 should not be entered as the actual outside dimensions. Neither designation establishes the measured clear aperture of an individual custom port.
Convert units explicitly when moving a catalogue entry to a drawing. Multiplying 2.75 inches by the exact conversion of 25.4 millimetres per inch gives 69.85 millimetres. A catalogue can reasonably call that size 70 millimetres. The rounded identifier is not a drawing tolerance and does not justify rejecting an accurately manufactured part. Ten inches converts to exactly 254 millimetres. For a critical fit, specify the actual part drawing and its dimensional limits. Where both inch and metric values appear in a purchase schedule, state which dimension and unit control the acceptance decision. Retain the original designation as an identifier so the part can still be found in the supplier’s catalogue.
Separate outside flange diameter from the opening the experiment or industrial instrument needs. A tube wall, internal step, gasket opening, port insert or transition can limit clear aperture at a different axial position. Draw a longitudinal section and identify the smallest usable opening over the distance the mating item occupies. A component that fits through the flange face can still touch a narrower internal transition. If the application needs a line of sight through the port, ask the owner to confirm the required clearance line and alignment. This simple exercise prevents selection based on a nominal size that was never intended to guarantee unobstructed internal space.
ISO 3669:2026 specifies dimensions for fixed and rotatable bolted knife-edge flanges in vacuum technology. The reference provides a basis for discussing interface dimensions. It does not identify the bore of every port modification or show that a particular welded chamber has passed a leak test. Keep the edition required by the controlled drawing. A legacy chamber may have been built to another edition or a particular manufacturer’s detail. If the original and proposed interfaces use different references, ask the engineering owner to confirm compatibility using the actual mating and sealing geometry before ordering the replacement. A current standard number on a quotation does not establish that all legacy hardware will fit.
Specify knife edge, gasket and bolting
An assembled CF-type joint seals when opposed knife edges act on an appropriate deformable metal gasket. A flange therefore has a functioning sealing feature beyond its flat exterior face. Protect that feature during handling and define how its condition is inspected on delivery. Identify gasket family, size and approved material for the particular mating parts. Copper gaskets are common in standard CF arrangements; the instrument manual cited below provides one documented example. Special materials and proprietary combinations need manufacturer confirmation. A generic package of metal washers with a similar outside diameter is not enough to identify a suitable vacuum gasket.
Show the bolt arrangement from a named face. Include the number and positions of holes, bolt circle, clearance or threaded condition, and exact thread designation for tapped holes. A bolt that passes through one flange and engages the other requires a different hardware set from two clearance-hole flanges secured with nuts. Verify access to the back of the joint after it is installed. If another part blocks nut access, a mechanically compatible pair of loose flanges can still be awkward or impossible to assemble in place. A drawing that identifies the accessible side often resolves the issue before the final flange form is chosen.
An angular datum makes a bolt pattern repeatable. Indicate whether a hole centre or the gap between two holes is aligned with a chamber axis, shield, instrument body or other feature. Identify the viewing direction so the angle cannot be mirrored when the flange is transferred to the fabricator’s drawing. A rotatable collar can provide alignment freedom in the bolt pattern, but cannot turn a fixed internal bore feature independently of the attached tube. If an insert or instrument has its own orientation, show it on the same assembly drawing. Mark which features rotate and which remain fixed after joining.
List the sealing and mounting consumables included in the purchase. One manufacturer may quote a bare flange and another may include the matched gasket and hardware. A maintenance technician who opens the package to find only the metal flange still needs the correct consumables before the joint can be completed. Confirm the manufacturer’s assembly instructions for the exact hardware and joint. The purchaser should not copy fastener torque or temperature limits from an unrelated stainless assembly onto a titanium flange. When repeated access is anticipated, document the owner’s gasket replacement and spare-parts arrangement with the applicable equipment guidance. This turns a one-off port purchase into a maintainable interface.
An example from an access drawing helps distinguish hole spacing and orientation. For an illustrative pattern of eight holes equally spaced around a circle, the angular pitch between adjacent hole centres is 45 degrees. Aligning a hole with the chamber’s vertical datum and aligning the gap between two adjacent holes places the pattern 22.5 degrees apart. Both layouts have eight holes on exactly the same bolt circle. A round blank may hide the difference until a fixed instrument on the other side is fitted. This is a geometric illustration, not the published hole pattern for either Atlas catalogue part. Obtain the actual manufacturer’s drawing for those parts.
If two companies exchange drawings, show a small view-direction arrow next to the angular datum. A useful review places the two projected mating faces together with one drawing viewed from the correct opposite side. Mark where a bolt goes through and where its thread ends. This quickly identifies an orientation or access discrepancy without needing to assign an arbitrary tolerance to the whole pattern. The chamber owner must still define the permitted angular and positional variation for the real instrument.
Choose the chamber-side attachment and orientation
Describe the chamber-side attachment as carefully as the mating seal. A flush-mount flange, a tube-mount flange and a weld-neck part place different features against the chamber or tube. The Atlas catalogue distinguishes these options. A supplier asked only for a DN and a material may choose a perfectly valid flange family and the wrong attachment for the customer’s construction. Supply the tube outside diameter, wall thickness and preferred internal transition where relevant. For a direct chamber mounting, provide a section through the wall, its material, available access and the intended location of the sealing face after joining.
An internal step can matter even when the two outside diameters match. Mark the intended bore alignment between tube and flange, any permissible transition and the surface that should remain flush. If a diagnostic instrument passes through, provide the instrument envelope and insertion direction. If a flange is deliberately blank, state whether an unbroken blank or one with a custom penetration is required. A penetration adds an interface and can alter the leak-test boundary and cleaning sequence. If future machining will be carried out by the customer, state which surfaces must remain protected and whether a previous test covers the part before or after that operation.
Joining a port to a thin chamber wall can change the location or orientation of the sealing face. Identify which features must be accepted on the loose flange and which are required after attachment. A supplier finishing only a loose part cannot measure the final orientation of a chamber it never sees. A chamber fabricator can be asked to inspect the face position relative to the system datum after joining. If wall material and flange material differ, obtain a defined transition design and specialist approval. A description such as titanium flange on metal chamber gives too little information to establish a suitable joining route or compatible materials.
Consider a chamber with two nearby instrument ports. Each loose component might meet its own nominal projection, while the two installed bodies interfere when the instruments are connected. Provide the surrounding envelope and the movement needed to install or remove each item. Identify which angular orientations are acceptable and whether the bolt heads can be reached with the adjacent unit installed. Where access is limited, agree a representative fit review of the assembled geometry. A full three-dimensional chamber model is not always necessary. A section plus a dimensioned front view can communicate which contact, clearance and service movements govern the purchase.
Set the material, cleaning and leak-test boundary
Write a materials list that mirrors the assembly section. Include the sealing body, edge, any collar, tube stub, gasket and fasteners included in the delivery. Identify the parts that see vacuum and parts on the exterior. If the chamber owner controls magnetic properties or contamination, ask what evidence it requires for those parts and in what condition. A named titanium grade is evidence of a material designation. It does not measure the magnetic response of every fastener, residue remaining after machining or outgassing of the completed assembly. Where evidence is needed, agree the method, scope and acceptance with the vacuum-system owner.
Specify cleanliness as an orderable deliverable. State the incoming application requirements, the agreed cleaning condition, protection for the sealing feature and how the package should be opened or stored. A general label such as clean or UHV ready may represent different practices at different shops. Ask which components are cleaned together, which substances or packaging materials the owner restricts, and whether a cleaning record follows the part. If a downstream workshop will weld or machine the flange after delivery, define when final cleaning occurs. It may be wasteful to pay for final-system cleaning of a loose blank that will undergo a contaminating operation before use.
Separate a leak-rate criterion from an intended operating pressure. Pressure describes a state in a volume; leak rate describes gas throughput under defined test conditions. Identify the units and distinguish a test result from a catalogue vacuum designation. A chamber may take longer to reach its intended pressure because of gas released by surfaces or because of its pumping arrangement. A low measured leak rate over one boundary does not by itself establish the final system pressure. Conversely, an observed chamber pressure alone does not locate a particular flange leak. Ask the vacuum specialist what measurement will answer the acceptance question for this purchase.
If testing is required, draw the boundary. A blank flange temporarily joined to a reference fixture, a welded port on a chamber and a complete chamber with feedthroughs are three different articles to test. Identify which seals and welds fall inside the boundary, the method, relevant conditions, acceptance criterion and identity of the tested item. Where helium testing is specified, request a report stating the applicable detector method, units, instrument verification and actual result or reporting limit under the agreed procedure. A certificate saying leak tested without describing the boundary leaves the buyer unable to determine whether the joint of interest was actually present during the test.
Compare offers and inspect the delivered interface
Compare quotations by the delivered part and its evidence. Place the mating interface, manufacturer designation or approved drawing, mounting form, clear bore, hole condition and angular orientation on the same line as the material and quantity. List the supplied gasket and hardware separately. Then add fabrication, cleaning, protection and test records. A lower price for a loose flange may be the right choice if the owner will fabricate its own chamber. It is a poor comparison with the price of a completed and tested port unless the cost of the remaining work is also included. Make assumptions and optional alternatives visible before awarding the order.
For receiving, inspect the protective cap or cover before exposing the seal. Match the part number, material record and drawing revision to the order. Check the agreed geometric characteristics, condition of the threads or clearance holes and identification of any separate collar. Use the approved acceptance method for the knife edge. A mark on the exterior handling rim and a mark across the sealing line have different implications. Record the location and seek the appropriate disposition if there is doubt about damage. Keep the sealing face protected until the qualified installation team is ready to use it.
For a repeat order, retain the part drawing and the mating port drawing together. Keep the original catalogue designation and any deviations the chamber fabricator approved. A modified flush-mount flange can still carry the nominal family name after the bore or bolt features change. If a supplier proposes a later catalogue revision, review the affected interfaces and material options before calling it interchangeable. When the old port is already on the chamber, photographs and previous inspection records can help explain the installation but should not replace the approved dimensions. The important deliverable is a replacement that mates, seals, remains accessible and can be verified under the contract.
For an enquiry, identify the process as an industrial or laboratory vacuum application and provide the intended mating part, attachment section and required records. State whether the scope ends at the protected loose flange, a welded tube assembly or a tested chamber port. If a parameter is not yet fixed, name it and request a priced option. A useful response can then separate catalogue geometry from custom work, identify the material of each part and price an appropriate inspection boundary. This gives the owner a technically comparable offer and a receiving team that knows which interface must be protected from the day the shipment arrives.
One final verification exercise is to follow the part through the actual installation. A technician should be able to identify the face that meets the copper gasket, the side from which each fastener enters, the datum that orients the tube and the test record that applies after joining. If the only drawing gives the outside diameter, all four questions remain open. If the purchased scope is a loose flange, mark post-weld checks as work for the chamber fabricator. If the scope is a finished assembly, place the same checks on the supplier’s acceptance schedule. That single distinction can explain a substantial price difference between two apparently identical titanium flanges.
Where the flange passes through an intermediate shop, identify who replaces the cover after inspection and records its condition before forwarding the part. A cleaning record for the first delivery may precede further handling at that shop. Keep loose gaskets identified by their own size and designation. Specify whether a fixture used during temporary testing is returned to the supplier or whether the tested accessories accompany the final delivery.
Inspection points
Agree the acceptance evidence before the first part is released.
Traceable from heat to shipment.
Manufacturer’s nominal flange size pairing, distinct from measured clear bore
Flush mount, listed 2.75 in / 70 mm, DN40Same mounting family, different nominal interface
Flush mount, listed 10.00 in / 254 mm, DN200The published 70 mm is a catalogue label. Use the part drawing for acceptance.
2.75 in × 25.4 = 69.85 mmCatalogue also describes an aluminium 6061-T6 rotatable collar option for clearance holes
Grade 2 flange and knife-edge face, Grade 5 by enquiryA dimensional reference and a measured assembly leak rate are separate evidence
Dimensional scope for fixed and rotatable bolted knife-edge vacuum flangesLink tubes or bundles to the heat / lot and protect the bore and ends.
Records + end caps + supportsSource documents
Check the applicable series, revision and scope against the purchase drawing.
Library PDFs may be earlier editions. Check the document cover and your contractual revision. A reference file does not certify a supplied product.
Explore all downloads ↗Technical sources
- Atlas Technologies — TICF-0275-04 — Manufacturer-listed flush-mount DN40 flange and inch/metric identifiers.
- Atlas Technologies — TICF-1000-04 — Manufacturer-listed DN200 interface, titanium grades and configurable collar materials in the family.
- ISO 3669:2026 — Current published dimensional standard for fixed and rotatable knife-edge vacuum flanges. Apply the edition agreed for the drawing.
- MKS / Kurt J. Lesker — 390 instrument manual — Instrument-specific distinction between O-ring KF and copper-gasket CF connections.
Baoji.
One contact.
TiHubs coordinates titanium sourcing through a local manufacturer network. Your specification guides the supplier review, technical discussion and delivery requirements.
Clarify the requirement
Confirm grade, dimensions, state, quantity and the purpose of the stock.
Review the supply route
Discuss manufacturing, finishing, inspection and documentation with the relevant supplier.
Agree the commercial scope
Confirm the quotation, lead time, acceptance requirements and delivery terms.
Coordinate inspection & delivery
Follow the agreed checks, marking, packing and shipment documentation.
Before you order
Specify a titanium CF vacuum flange by mating interface, outside diameter, gasket, mounting and bolt pattern. Compare published DN40 and DN200 examples, cleaning and leak-test evidence.

TITANIUM VACUUM FLANGES · BAOJI SOURCING
Send your specification.
Send the mating port or component drawing as well as the nominal size. Identify the knife edge and gasket, flange orientation, tube or chamber interface and the boundary that must be leak tested.