CategoryQuality, Inspection & Standards
Titanium flange replacement:
match every interface.
Identify the complete connection before ordering: drilling, bore, sealing face, axial envelope and the approved material and design basis.

Quick answer
Specify a titanium flange replacement using the approved drawing, standard and edition, flange type, nominal size, rating designation, material and manufacturing form. Confirm bolt-circle diameter, hole count and size, bore, neck, sealing face, gasket interface and axial envelope. Following a standard drilling pattern does not automatically establish the pressure qualification of a custom titanium part. Keep dimensional compatibility, material evidence, design approval and assembly requirements connected, and obtain a controlled disposition for every proposed change before shipment.
01 / Standard and drawing
Identify the complete connection, not only its nominal size.
A maintenance enquiry asks for a titanium flange to replace a corroded component on an existing line. The buyer knows the nominal pipe size and can count the holes, but the drawing is missing. A supplier offers a flange with the same size label. Before ordering, identify the full connection: standard and edition, flange type, rating designation, material basis, drilling, bore, sealing face and installed envelope. Matching one label does not establish that the new part will connect or that it is approved for the service.
Start with the equipment records, original drawing, line specification and markings that can be read reliably. Record the reason for replacement and whether titanium is already the approved material or is a proposed change. Preserve the original part number and revision. Photographs and measurements can help resolve identification, but corrosion, previous machining and site modification may make the removed part an imperfect reference. Mark uncertain details explicitly so a preliminary sketch is not mistaken for a released manufacturing drawing.
ASME B16.5 covers a defined range of pipe flanges and flanged fittings and addresses more than dimensions, including materials and pressure-temperature ratings. Its public scope also limits the manufacturing forms covered. An enquiry should distinguish compliance with an applicable complete specification from a custom titanium component whose dimensions follow a selected pattern. Copying the bolt drilling of a standard flange does not automatically provide its material coverage or pressure qualification. The responsible piping engineer must establish the acceptance basis. [1]
PN-designated and Class-designated systems must remain identifiable. BS EN 1092-1 concerns steel flanges; its dimensional conventions should not be cited as blanket titanium material approval. Do not translate a PN designation into a Class label using a simple pressure conversion. Even where nominal sizes appear comparable, the actual drilling, face, bore and thickness can differ. If a custom part uses dimensions from one system, state exactly which dimensions are adopted and which project document governs its material and design. [2]
| Identification layer | Information to preserve |
|---|---|
| Equipment requirement | Line or nozzle reference, drawing and revision |
| Dimensional basis | Standard, edition, size, type and applicable series |
| Design basis | Approved material and pressure-temperature requirement |
| Mating interface | Drilling, bore, face and gasket arrangement |
Larger connections may use a different standard family. ASME B16.47 addresses large-diameter steel flanges, so a large size should not simply be extrapolated from a smaller B16.5 table. Preserve every series designation that appears on the approved drawing and verify the relevant dimensions in the controlled document. Avoid mixing dimensions from different tables to obtain a convenient fit. A replacement enquiry becomes much easier to evaluate when it identifies one governing connection description and lists any deliberate deviations separately. [3]
02 / Bolt pattern and alignment
Measure the bolt circle as well as the hole count.
The drilling pattern needs at least the number of holes, hole diameter, bolt-circle diameter and angular arrangement. Outside diameter alone does not define it. Two flanges can have equal outside diameter and hole count while placing their holes on different circles. They can also share a bolt circle but have different hole diameters or orientation relative to a nozzle or adjacent feature. Record each characteristic instead of assuming that a familiar visual pattern identifies a standard.
Use a sketch with a clear center and datum. The pitch-circle diameter, often abbreviated PCD or BCD, runs through the hole centers. It is different from the outside diameter and from an edge-to-edge measurement between holes. Where an even, equally spaced pattern has opposite holes, a center-to-center measurement across the diameter can help identify the circle. The inspection method must account for hole size, access and measurement uncertainty; the sketch should state which actual distances were measured.
An original geometry example shows the scale of a mismatch. For n equally spaced holes on a circle of diameter D, the adjacent center-to-center chord is c = D × sin(π/n). With eight holes on a hypothetical 200 mm circle, c is approximately 76.54 mm. With eight holes on a 190 mm circle, it is approximately 72.71 mm. The same hole count therefore hides a 3.83 mm difference between adjacent centers. These numbers are illustrative, not dimensions from a flange standard or an instruction to modify a connection.
If an adjacent chord is used to estimate the circle, D = c/sin(π/n), but only after confirming the number of equally spaced holes and that the measured chord joins adjacent centers. A measurement across two or more intervals needs a different angular term. Do not apply the shortcut to an irregular pattern or an uncertain edge measurement. For an actual acceptance inspection, use the method and tolerances specified by the approved drawing rather than treating this identification calculation as sufficient evidence.
| Drilling detail | Why it matters |
|---|---|
| Number of holes | Must match the approved fastening pattern |
| Hole diameter | Defines the specified fastener clearance |
| Bolt-circle diameter | Locates centers relative to the flange axis |
| Angular orientation | Relates the pattern to installation datums |
| Position tolerance | Controls the permitted departure from nominal geometry |
Bolt clearance is not permission to compensate for an incorrect circle. If the supplied pattern does not match, stop the fit review and resolve the discrepancy with the responsible engineer. Do not enlarge or slot holes, force bolts into place or use tightening to pull a misaligned connection together as an informal workaround. Such changes alter the approved geometry and may affect the joint. Record the measured mismatch and obtain a controlled disposition before any rework.
For remote enquiries, request photographs taken approximately square to the face and include a scale for orientation, but keep measured dimensions in a separate table. Camera perspective can make a circle appear elliptical and cannot provide a reliable acceptance measurement by itself. If the original mating flange remains installed, document how its reference dimensions were obtained and which items still require confirmation during the planned maintenance inspection.

Hypothetical eight-hole circles: 200 mm and 190 mm produce adjacent center chords of about 76.54 mm and 72.71 mm. Not standard flange dimensions.
03 / Bore, neck and installed envelope
Match the pipe connection and the space it occupies.
The central opening is only one part of the pipe interface. For a weld-neck flange, the required bore and welding-end geometry must match the approved pipe and joint preparation. A slip-on or socket arrangement has a different interface, and a blind flange has no process bore. A lap-joint arrangement includes a separate mating component whose geometry must be identified. Preserve the flange type from the drawing rather than replacing it with whichever type is easiest to source.
State the actual pipe outside diameter and wall requirement alongside the nominal designation when they control the connection. A Schedule label needs its dimensional standard and cannot be treated as a universal wall thickness. If the existing line uses a custom wall or a tube outside-diameter system, identify that directly. The TiHubs pipe-dimensions guide explains why NPS, DN, outside diameter and wall are separate fields. The flange order should carry the values approved for the actual joint.
Record the bore, neck dimensions, overall length and welding-end preparation required by the manufacturing drawing. Do not derive a bevel or transition from a photograph when a controlled joint detail is needed. The welding procedure and design requirements should establish the appropriate preparation. If the supplier proposes a different bore or neck configuration, request a marked-up drawing showing the difference so the reviewer can evaluate it before machining.
The installed envelope also includes the distance from the sealing reference to the pipe connection, adjacent equipment and available bolt access. A part can have correct drilling and still move the sealing plane or obstruct a tool. Identify the reference planes used for each axial dimension. On a raised-face component, clarify whether the drawing’s thickness or overall length includes the raised portion. Do not compare two catalogue dimensions until their measurement conventions are understood.
| Interface | Data to put on the drawing |
|---|---|
| Pipe or tube | Outside diameter, wall and governing designation |
| Welding end | Bore, preparation and approved transition details |
| Axial envelope | Reference planes, flange thickness and neck length |
| Installation clearance | Adjacent components, fastener and tool access |
| Separate components | Stub end, backing ring or other specified parts |
A hypothetical layout check can expose a hidden difference without performing a pressure calculation. If an approved assembly drawing locates the sealing plane 75 mm from a pipe reference, an offered part placing it at 80 mm changes the axial position by 5 mm. Whether the system can accommodate that change is a design and installation question. Do not assume a gasket, extra tightening or movement of the connected pipe will absorb it. Flag the difference and preserve the original dimension until a change is approved.
When ordering a replacement pair, inspect both sides of the interface. Two new matching flanges may connect to each other but still conflict with the retained pipe, valve or equipment nozzle. List which components remain and which are replaced. That boundary helps the supplier quote the correct machining scope and prevents a successful bench fit from being mistaken for confirmation of the complete installed arrangement.

Check drilling, sealing face and pipe connection against the approved drawing. The diagram is schematic and provides no pressure rating.
04 / Sealing face and gasket
Specify the sealing system as a matched interface.
The sealing face needs a complete description, not simply a request for a smooth finish. Identify the face type, relevant diameter, height or recess, surface-finish requirement and any groove geometry. Raised face, flat face and ring-type-joint arrangements are not interchangeable labels. The mating flange and approved gasket must be considered together. A replacement that shares the drilling but changes the sealing interface can require a different design review and assembly condition.
Garlock’s technical material distinguishes flange-face arrangements and the gasket interfaces they create. The purchasing lesson is to preserve the approved pairing rather than select a gasket by nominal pipe size alone. Record the required gasket standard or drawing, material, dimensions and applicable service requirement. If the gasket is supplied separately, identify who verifies the match. Do not describe a quotation as a complete joint set when the sealing component remains unspecified. [4]
Surface finish should be stated using the specified parameter, units and acceptance range. A roughness number without its parameter can be ambiguous, and a visual description such as mirror finish is not an adequate replacement. Where a particular lay or machining pattern is required, include it. Do not assume that polishing improves every gasket interface; the approved gasket and flange requirements establish the acceptable condition. Ask the supplier to identify the inspection method when finish is a contractual acceptance characteristic.
Preserve groove identification and dimensions where a ring-joint or other confined seal is involved. A similar-looking groove can still differ in the details that control the gasket fit. The used gasket is not necessarily a reliable dimensional master because it has been compressed and exposed to service. Use the controlled drawing or approved seal designation, supported by inspection of the actual mating interface. Any proposed groove repair or face machining should receive a defined technical disposition before work begins.
| Sealing requirement | What the enquiry should state |
|---|---|
| Face geometry | Type, diameter, height, recess or groove designation |
| Surface condition | Specified roughness parameter, units and pattern |
| Gasket | Approved material, dimensions and identification |
| Mating side | Retained flange material and face configuration |
| Acceptance | Inspection and disposition of face damage |
Protect the finished face during handling and transport. Specify suitable covers and packaging that prevent contact damage while preserving identification. At receiving, check the agreed face condition before the component is placed in general storage. If scratches, dents or corrosion are found, document their location and refer them to the acceptance procedure. Do not assume that any mark can be removed by local sanding or that a thicker gasket is an approved correction.
Assembly requirements belong to the same interface review. ASME PCC-1 provides guidance for a defined scope of pressure-boundary bolted flange joints and can support an appropriate assembly procedure when applicable. It is not a universal instruction for every face and gasket configuration. The project must specify the actual assembly method, bolting and verification. This buying guide does not provide a generic torque, gasket substitution or leak-test procedure. [5]
05 / Material and design basis
Separate titanium material evidence from pressure qualification.
A flange described as titanium Grade 2 still needs its material specification, manufacturing form and condition. A forging requirement is not automatically satisfied by machining a visually similar ring from plate or bar. Conversely, a design that permits a particular plate-made component should state that route explicitly. Preserve the approved product form in the purchase order so a lower-cost alternative does not become an unreviewed change in the manufacturing basis.
ASTM B381 covers titanium and titanium-alloy forgings and uses forging-grade designations such as F-2. Its public scope addresses material composition and mechanical requirements. That material specification does not by itself define the entire flange geometry or establish a pressure-temperature rating for an assembled joint. Keep the material requirement, component drawing and governing design basis as separate, connected documents. The supplier’s declaration should state which scope it actually covers. [6]
For a replacement involving a change from steel to titanium, ask the responsible engineer to establish material acceptability and the applicable design route before treating the part as equivalent. A steel flange’s class designation cannot simply be copied onto a custom titanium part because the dimensions match. The complete review may involve the governing piping or equipment code, allowable material properties, geometry, service conditions and the mating components. Purchasing should request the approved result, not substitute a general marketing claim for that work.
Pressure and temperature need to remain paired in the service information. A pressure value without its temperature and design context is incomplete. Also identify the relevant process medium, corrosion allowance where specified, external loads or other project conditions that the design authority requires. Do not turn those fields into an online pressure-rating calculation unless an approved, applicable method and all inputs are available. The RFQ can carry them as controlled requirements for the supplier and reviewer to address.
| Document | Its useful role | What it does not establish alone |
|---|---|---|
| Material record | Identity and stated material properties | Complete flange design approval |
| Dimensional report | Conformity to the specified geometry | Permitted pressure at every temperature |
| Design approval | Approved basis for the defined component and service | Conformity of every delivered lot |
| Assembly record | Completion of the specified installation checks | Missing material or design evidence |
Define any nondestructive examination, additional testing or inspection hold points required by the project. A generic request for fully tested material is too vague to compare. State the method, scope, acceptance basis and responsible reviewer where required. Do not claim that a particular examination is included by default merely because it is commonly mentioned in flange advertising. The supplier should identify the tests included in the quotation and any exclusions before the order is placed.
Traceability should connect the finished component to the material and inspection records within the required scope. Agree the marking content and location so identification does not damage a sealing surface or other controlled area. If the part is machined from an identified forging, preserve the transfer of identity through machining and packaging. A clear traceability chain makes it possible to assess the delivered flange against the approved requirement rather than relying on an attractive product label.
If the replacement follows leakage or repeated maintenance, preserve the failure observations separately from the proposed solution. Record where leakage occurred, which components were retained, whether the face was damaged and what maintenance records are available. A leak does not by itself prove that the flange alloy was unsuitable. The joint owner should review the relevant evidence before changing material, face geometry or gasket. Purchasing can then quote the approved corrective scope instead of buying a visually similar part that leaves the original cause unresolved. This also helps distinguish a required replacement from optional changes proposed during the same shutdown.

Connect material identity, dimensional conformity, approved design and assembly verification. No single record substitutes for every other requirement.
06 / Inspection and ordering
Use one drawing and close deviations before shipment.
Build the enquiry around a controlled drawing or an approved standard description with all necessary supplementary details. Include part reference, revision, quantity and destination, then identify material, flange type, dimensional basis, drilling, bore, face and documentation. If information is still being collected from an existing installation, mark the request preliminary. Ask suppliers to list assumptions explicitly so they can be resolved before the quotation becomes a manufacturing order.
A dimensional checklist should follow the interfaces that matter. Check outside diameter and thickness, bolt-circle diameter, number and size of holes, orientation, bore, neck or connection dimensions, face geometry and overall envelope as applicable. Record drawing tolerances and inspection references. Do not copy a table from another size or material to fill an empty field. If the drawing and standard reference conflict, obtain a clarified revision from the responsible authority rather than asking the shop to choose.
| Comparison field | Requested | Offered | Disposition |
|---|---|---|---|
| Standard/type/material | Approved requirement | Exact supplier scope | Accepted or review pending |
| Drilling/bore/face | Drawing dimensions | Confirmed dimensions | Differences identified |
| Inspection/documents | Required evidence | Included records | Missing items resolved |
| Quantity/delivery | Accepted finished pieces | Packaging and schedule | Commercial scope aligned |
For a first article, agree whether the review is dimensional, documentary, assembly-related or a combination. A bench fit can reveal drilling or access problems, but it does not establish the component’s design pressure or service life. Identify the mating part used in the check, the drawing revision and the acceptance record. If production is conditional on first-article approval, make that hold point visible in the order and do not assume that receiving a sample automatically releases the remaining batch.
Receiving should compare the delivered flange and its records with the same requirement used for quotation. Check identity, quantity, protection and the specified inspection results before release to installation. Preserve face covers until the handling procedure requires removal. If damage or a dimensional discrepancy appears, keep the component identified and record the condition. Unapproved local rework can obscure both the original problem and the evidence needed for a fair supplier disposition.
Make the supply boundary explicit when requesting a kit. State whether the scope includes gasket, studs or bolts, nuts, washers, backing ring or other components. Each must have its own approved requirement where applicable. The fastener replacement checklist can help organize the bolting fields, but the flange-joint design and assembly procedure govern their selection. A quotation for one titanium flange should not be interpreted as a complete, qualified joint assembly.
After approval, retain the final drawing, supplier deviations and accepted records with the repeat-order description. A later change in material source, manufacturing route where controlled, face finish or drilling must follow the agreed review process. For a supply assessment, send the defined requirement through the enquiry below or review TiHubs titanium flange products. The practical objective is a component whose identity, geometry and evidence match the approved installation requirement.
07 / Build your RFQ
Prepare a titanium flange replacement enquiry.
Send the approved drawing or original part reference with the full connection description. Include material and manufacturing form, drilling, bore, facing, quantity, required records and destination. TiHubs can review the defined supply scope. If the component is a proposed material substitution or a custom design, identify the approval status so the quotation does not imply an established pressure rating.
Information to include
- Part reference, drawing revision and governing standard
- Flange type, nominal size and rating designation
- Approved titanium material, form and design basis
- Hole count, hole size, bolt circle and orientation
- Bore, neck, face, gasket and axial reference dimensions
- Inspection, documentation, quantity and destination
Build your RFQ checklist
Choose the product and add the information you have. Copy the resulting brief or send your requirements to TiHubs. Submitting an enquiry does not place an order.
08 / FAQs
Questions buyers ask
Does matching the bolt pattern establish the pressure rating?
No. Drilling establishes only part of dimensional compatibility. Material coverage, manufacturing form, design rules, pressure-temperature conditions and the assembled joint must satisfy the approved basis. A custom titanium flange cannot inherit a steel flange rating merely by sharing its dimensions.
Can PN and Class designations be converted directly?
Do not use a simple numerical pressure conversion to select a replacement. The systems have their own dimensional and rating requirements. Preserve the original standard, size, type and designation, then check the actual mating dimensions and approved design basis.
What is the difference between flange OD and bolt-circle diameter?
Outside diameter describes the outer edge of the flange. Bolt-circle diameter passes through the hole centers. Equal outside diameters and equal hole counts do not guarantee matching hole locations, so both dimensions and the angular pattern must be verified.
Can a used gasket identify the correct sealing interface?
It can provide context, but compression and service exposure may alter it. Use the approved gasket designation and flange drawing, supported by inspection of the mating face. Do not infer a groove or surface-finish requirement solely from an old gasket.
Does ASTM B381 certify the complete flange design?
It is a titanium-forging material specification within its defined scope. It does not alone establish the entire flange geometry, joint assembly or design pressure. Request the required material evidence together with the dimensional and approved design documents.
What should be supplied for a replacement quotation?
Provide the controlled drawing or complete approved connection description, material and form, drilling, bore, face, gasket interface, quantity and documentation. State which adjacent components remain and identify any unresolved assumptions or proposed substitutions before manufacturing.
09 / Key takeaways
Keep the purchase requirements connected.
- Identify the complete approved connection and revision.
- Check drilling, bore, face and installed envelope separately.
- Keep material evidence distinct from pressure qualification.
- Preserve the approved gasket and assembly interfaces.
- Close deviations and retain lot-linked inspection records.
Technical references
Sources and data scope
References reviewed November 13, 2026. Public source summaries support the discussion; the controlled specification, agreed edition and approved project requirements govern acceptance.
- ASME B16.5-2025 — Pipe flanges and flanged fittings — Public scope includes dimensions, materials, ratings and manufacturing-form limits; project applicability must be established.
- BSI — BS EN 1092-1:2018, steel flanges — Primary scope for PN-designated steel flanges; not a blanket titanium-material approval.
- ASME B16.47 — Large-diameter steel flanges — Identifies a separate large-size standard family and its material scope.
- Garlock — Metallic gasket technical manual — Describes flange-face interfaces and information required for gasket selection.
- ASME PCC-1 — Pressure-boundary bolted flange joint assembly — Assembly guidance with a defined applicability scope; use the approved project procedure.
- ASTM B381 — Titanium and titanium-alloy forgings — Public material-specification scope; the purchase must identify its required edition and grade.
